产品详情
Parameters Condition Specs Units Min Typ Max Number of Channels 40 Number Channel Spacing 100GHz 100 GHz Cha. Center Wavelength ITU frequency. C -band nm Clear Channel Passband ±0.1 nm Wavelength Stability Maximum range of the wavelength error of all channels and temperatures in average polarization. ±0.05 nm -1 dB Channel Bandwidth Clear channel bandwidth defined by passband shape. For each channel 0.4 nm -3 dB Channel Bandwidth Clear channel bandwidth defined by passband shape. For each channel 0.6 nm Optical Insertion Loss at ITU grid Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarization. 4.5 6.0 dB Adjacent Channel Isolation Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarization, within the ITU band of the adjacent channels. 25 dB Non-Adjacent, Channel Isolation Insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarization, within the ITU band of the nonadjacent channels. 30 dB Total Channel Isolation Total cumulative insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarization, within the ITU band of all other channels, including adjacent channels. 22 dB Insertion Loss Uniformity Maximum range of the insertion loss variation within ITU across all channels, polarization and temperatures. 1.0 1.5 dB Directivity(Mux Only) Ratio of reflected power out of any channel(other than channel n)to power in from the input channel n 40 dB Insertion Loss Ripple Any maxima and any minima of optical loss across ITU band, excluding boundary points, for each channel at each port 0.5 dB Optical Return loss Input & output ports 40 dB PDL/Polarization Dependent Loss in Clear Channel Band Worst-case value measured in ITU band 0.3 0.5 dB Polarization Mode Dispersion 0.5 ps Maximum Optical Power 23 dBm MUX/DEMUX input/ output Monitoring range -35 +23 dBm IL Represents the worst case over a +/-0.1nm window around the ITU wavelength PDL was measured on average polarization over a +/- 0.1nm window around the ITU wavelength. Ordering Part Code Sequence AWG X XX X XXX X X X XX Band Number of Channels Spacing 1st Channel Filter Shape Package Fiber Length In/Out Connector C=C-Band L=L-Band D=C+L-Band X=Customize 16=16-CH 32=32-CH 40=40-CH 48=48-CH XX=Special 1=100G 2=200G 5=50G X=Special C60=C60 H59=H59 C59=C59 H58=H58 XXX=special G=Gaussian B=Broad Gaussiar F=Flat Top M=Module R=Rack X=Special 1=0.5m 2=1m 3=1.5m 4=2m 5=2.5m 6=3m S=Specify 0=None 1=FC/APC 2=FC/PC 3=SC/APC 4=SC/PC 5=LC/APC 6=LC/PC 7=ST/UPC S=Specify
产品所属分类: 传媒、广电/ 有线光缆设备/ 光纤波分复用器
- 珠海飞宇光电科技有限公司
- 联系人 : 卢艳
- 手 机 : 15920024966
- 电 话 : 0755-29048607
- 传 真 : 075529048624
- Email : jessice@opticres.com
- 地 址 : 广东深圳市宝安区龙华鹊山路口太阳能硅谷大厦A座14楼
- 邮 编 : 200002
- 传众商铺 : 11666133.czvv.com